I pressed 6 on a sky130 schematic and xschem answered, in the console:
These symbol types have no operating-point values to show: capacitor, high_precision_poly_resistor, nmos, pmos and more.
Read quickly, that says the sky130 FETs cannot show operating-point annotation. My message to Claude was more or less "No kidding?". The IHP cells in the same project annotate fine. Same tool, same build, same simulator. Why would one process be a second-class citizen?
It was not. The feature is table-driven, and the table for sky130 had never been loaded into that xschem session. This post is about how we found that out, what we changed, and the handful of lessons that are worth more than the fix.
How the annotation knows a FET
To put gm or vth next to a transistor, the tool has to know two things that are different for every process: how the simulator spells that device in the results (for a sky130 wrapper it is @m.x1.xm1.msky130_fd_pr__nfet_g5v0d10v5, for IHP's PSP model it is @n.x1.xm1.nsg13_hv_nmos), and which quantities to ask for. Each PDK workarea ships a small descriptor that answers both, keyed by the symbol type (nmos, pmos), and registers it when the workarea's rc file is sourced. The same descriptor is what puts the device requests into the simulation deck, so without it a run saves nothing per device either.
Two details made the symptom confusing. First, the key is the symbol type, and both PDKs use nmos. So the registry holds one descriptor per type, and registering a second PDK replaces the first. The tool's own spec calls this out as "one interpreter per PDK", and it degrades to blank rather than to wrong numbers, which is the right failure. Second, a descriptor only claims cells whose name matches its PDK's library glob. Our project's startup script sourced the IHP workarea rc and nothing from sky130. The IHP descriptor looked at a sky130_fd_pr cell, declined it, and the annotator reported the type as one with nothing to show. Which, in that session, was true.
The tool had said so already. The run log in the console carried this line, printed at netlist time, before anyone pressed a key:
ASE: no device below this cell produced an OP save card — no registered op_annot PDK descriptor matched, or nothing below it is annotatable. The deck asks for no device parameters.
Nobody read it. Two sentences in a console pane, between a hundred others.
The fix I did not want
Claude's first proposal was an environment variable, with the PDK inferred from the schematic path when the variable was absent: a cell under lib/hdo_sky130/ would get a sky130 session, anything else IHP. Reasonable on paper. I turned it down. A setting that decides what a whole session can do should not be inferred from where a file happens to live, and a wrong guess here fails silently: the editor works, the simulation works, and the FETs quietly stop annotating. We already had the right model in the xschem repo: a small Tk launcher where you pick a PDK and press Launch. So:
Make it a minimal GUI like the pdk_launcher.sh thing in the Xschem repo. I'll pick the PDK when I run the launcher.
The dialog is about a hundred lines of Tcl. It exports the choice as two environment variables, the project's rc file resolves the matching workarea and switches the fresh-state simulation defaults with it, and the startup script sources that workarea's rc instead of a hard-coded one. One session, one PDK, chosen on purpose and visible in the command line.
Proving it, and the proxies that lied
The first three attempts to verify the fix all drew the six-row block with every value blank. Each attempt was a shortcut: run the bench headless, then load the cell and call the annotation. The deck and results were right. The shortcut was wrong twice over. The annotator finds its results file through the simulation session that owns the sheet, and a run started outside such a session left it looking for a file the simulator never writes. And the annotation has to be issued in the design window the simulation environment opens, not after a bare load into the main one. Only the user's own path proved anything: open the state in the simulation environment, Netlist and Run, open the design window, descend into the cell, press 6.
![]() |
| The whole cell. The console sentence now names only the capacitor, the resistor and the probe, which is what it should say. |
One more thing the verification turned up, and it would have fooled a deck-grepping check forever: on this ngspice build the device numbers never appear as .save cards in the deck at all. The simulation environment measures that the simulator can dump every device's operating point in one go, asks for that instead, and the values land in a small .opinfo file beside the raw. The deck looked empty of device requests and was fine.
What three reviewers found
Before calling it done we ran three independent reviews: one on the launcher code, one on the tool-side assumptions against the xschem source, one on the write-up against the evidence. None of the three found the fix wrong. All three found something the author's tests could not:
- The launcher did not change into the project directory before starting xschem, so the project's own operating-point parameter lists, which the tool reads from
./.xschem, were silently skipped unless you happened to start from the project root. - Return with the keyboard focus on Quit launched xschem instead of quitting. Inherited from the launcher we copied.
- The project's parameter-list settings carried rows spelled for IHP's model, unscoped, so a sky130 session would have asked BSIM4 for quantities it does not publish. One section header fixed it.
The lessons
- A "cannot" from a tool is usually a "was not told". Before concluding that a feature does not support something, find who was supposed to register, configure or load it, and check whether that happened in this session.
- Read the console at run time. The cause was printed before the question was asked. A notice you do not read is a notice the tool did not print.
- Session-wide settings get an explicit choice, not an inference. One click in a dialog, with the resulting command visible, beats a clever rule whose failure mode is silence.
- Verify through the user's path, not a proxy. Three shortcuts produced blank values and looked exactly like a broken feature. The feature was fine; the probes were not the user.
- A table-driven feature has a scope. Here the scope is one xschem process, one registry, one PDK. Know the scope before you ask why something is missing from it.
- Independent review earns its cost on infrastructure. A launcher that every session goes through is worth three readers. A two-component schematic edit is not.
Total time, from the question to the memory note: about ninety minutes, then the review. The fix itself was a day's worth of understanding compressed into a dialog with two radio buttons.